P. 26 Installation Guide
Note: For Hardware 5.0 and higher, there can only be one bypass connected to the unit.
Multi-car Operation
This option allows the owner of two vehicles, both equipped with identical systems, to control both
systems with only one remote transmitter. (see user guide for operation)
Note: See transmitter programming section on how to learn the transmitter to the second car.
Intrusion Codes via LED light
The system monitors the following:
Any vibrations sensed by the shock sensor such as someone breaking the window,
windshield, etc.
Doors
Ignition
Hood
Note: If an intrusion has occurred the siren will sound for a maximum of 1minute.
When an intrusion has occurred, pressing unlock will make the siren chirps four times. The
antenna’s LED will provide an intrusion code corresponding to the type of the intrusion that
occurred. The LED intrusion codes are flashed in continuous loops.
2 x = Doors intrusion
5x = Panic
3 x = Shock Sense
6x = Ignition
4x = Hood
Diagnostics via parking lights
Diagnostic table for shutdown.
Parking lights flashes
Cause
1
Runtime has expired.
2
Shutdown by remote.
Ready mode is activated.
3
Failed start.
4
Brake shutdown.
10
Hood shutdown.
Flash for 30sec
Panic mode
Flash for 60sec
Alarm triggered
Diagnostic table for start failure.
Parking lights flashes
Cause
1
(Manual transmission only)
Ready mode is not activated.
Tach signal is not learned.
1 slow 2 quick
The system is set to valet mode.
3
(Automatic transmission
only)
The parking brake is active.
Yellow loop is connected.
4
Brake wire is active
Page view 25