p.12 CT-3271
12-Pin Accessories Harness
Wire
Description
1
BLUE (–)
AUX 3
(Trunk)
output
500 mA negative output. This output can be used to control Trunk
release (1-sec. pulse).
Note: AUX 3 (TRUNK) operates only when Ignition is OFF or when the
vehicle is running under remote control.
2
BROWN (–)
Lock
output
Programmable 500 mA, 7/10sec., or 4 sec negative outputs.
3
GREEN (–)
Unlock
output
Programmable 500 mA, 7/10sec., 4sec., or double 1/4 sec. pulse
negative output.
4
WHITE /
BROWN
(–)
Arm output
500 mA ground output when the button is pressed. This output is
activated 500 ms before the LOCK pulse and deactivated at the same
time as the LOCK pulse ends.
Note: The system will also give an ARM/REARM pulse on this wire
when it shuts down the vehicle after a remote start.
5
WHITE /
GREEN
(–)
Disarm
output
500 mA ground output when the button is pressed. This wire is for
disarming OEM Alarm systems.
Note: System will also give a DISARM pulse before remote start.
6
BLUE /
WHITE
(+)
Positive
Door input
This input should be used in vehicles that use a positive-switching
Dome Light circuit. Connect to a Dome Light wire testing +12 V with a
Door open.
CAUTION! You can only use either the NEGATIVE DOOR INPUT or
the POSITIVE DOOR INPUT wire. It is essential that the Module be
connected in such a way as to allow each one of the Doors to be
detected by the remote starter.
7
WHITE /
ORANGE
(–)
Starter Kill
output
The unit is equipped with a selectable passive- or active-arming Starter
Kill circuit that will immobilize the vehicle when the system is armed.
This wire will provide a constant 500-mA negative output when the
system is armed (locked by remote) or if remote started. This wire
should be connected to a Single Pole Double-Throw Relay (This wire
will connect to Pin 85, on the Relay, and Pin 86 will be connected to the
Ignition wire).
A second benefit of the Starter Kill is the Anti-Grind feature. When the
vehicle has been remote started the Anti-Grind prevents the starter
motor from re-engaging when the ignition key is inserted in the Ignition
switch and accidentally turned to the CRANK position (The Starter Kill
output becomes active during remote starts).
8
ORANGE
(–) Parking
Brake
input
This input is for manual transmission vehicle ONLY. It is used in the
Ready Mode sequence and must be connected. The Parking Brake
input must be given a ground signal (-) when the Parking Brakes are
applied.
9
PURPLE
(–)
External
Trigger
input
The External Trigger wire can be used for remote-starting/ stopping the
vehicle with an external device. When the vehicle is running, triggering
this input will also activate Idle Mode.